MINGDA

Coated and laminated protective fabric, aluminised and coated constructions

Aramid, pre-oxidised and high-strength substrates · Aluminised, PU-coated and TPU-coated laminates · 250 – 2,000 g/m² recorded across the range · Every construction tested as a complete assembly

Our coated and laminated class: aluminised, PU-coated and TPU-coated constructions built on inherently flame-resistant or high-strength substrates. Supplied with the material data for the construction you order, on the rule that decides this class — a laminate is one assembly and is assessed as one.

  • Aluminised and coated laminates on aramid, pre-oxidised and high-strength substrates
  • TPU and PU coated builds from 380 to 2,000 g/m²; aluminised builds from 300 to 530 g/m²
  • Base-fabric data does not transfer: the laminate is tested as a complete assembly
Aluminised protective fabric, aluminium foil laminated face
Aluminised (覆铝箔面料) Aluminium foil lamination · radiant heat reflection
Aluminised pre-oxidised and para-aramid fabric, rolled
Aluminised roll (覆铝箔卷材) Pre-oxidised fibre and para-aramid substrate
Coated abrasion-resistant fabric, composite weave face
Coated weave (涂层耐磨面料) Composite weave · cut and puncture resistant
Black coated UHMWPE and polyester fabric, rolled
Coated roll (涂层卷材) Single-sided coating · cut and puncture duty

The material

A coating or a laminate is a new construction, not a treated cloth

The sentence that decides this class is short: a flame-resistant base fabric does not make a flame-resistant laminate. Coating a cloth or bonding a membrane to it adds a component with its own combustion behaviour, and that component can make the whole construction worse — a coating that burns, drips or raises smoke density changes the result even when the substrate under it is inherently flame resistant. It works in the other direction too, which is why this class is worth specifying: an aluminium-foil lamination substantially improves radiant-heat performance, and the aluminised builds in the range are the ones that reach the higher radiant-heat bands. Nothing in this class can be inferred from the composition, and no figure can be carried across from a substrate to a laminate. Every coated and laminated construction is measured as a complete assembly.

What a laminate is matters more here than on a plain cloth, because there are three components doing work. The substrate carries the strength, the coating or the foil decides the surface behaviour, and the adhesive or the bonding route holds the two together — and the laminate takes its properties from all three. Our substrates are the ones we make: para-aramid (aramid 1414) woven cloth, which is inherently flame resistant; aramid and pre-oxidised felt; and UHMWPE (HPPE) woven cloth, which is a cut-and-abrasion material and not a flame-resistant one. A coated UHMWPE construction is therefore a mechanical-protection laminate and is labelled as such on this page, because a buyer who takes it for an FR construction would be buying the wrong material.

Chemically, this is the class we screen hardest, and it is worth saying why. A coating or a membrane is itself an article for REACH purposes: in a complex article the 0.1% threshold is checked against each constituent article rather than against the whole, so the coating, the adhesive and the substrate each have to be accounted for. PVC and flexible coatings commonly use phthalate plasticisers, and several phthalates are on the SVHC candidate list; a laminating adhesive can carry SVHC as well. That is why we work from the coating supplier’s own safety data sheet and substance declaration, and why the declaration we issue is issued for the exact article supplied rather than for the class. Azo dyes under REACH Annex XVII entry 43 are a tested route for a dyed or coated cloth. RoHS is not a regulation that applies to textiles, so this page states no RoHS position for a coated article; where a programme screens for phthalates, the answer is the substance declaration for the construction.

What we supply is material data for the construction: substrate, coating or foil, weight, width and roll form, plus the test report for the production lot. What a laminate does under a flame, a radiant heat source, a water jet or a chemical splash is established by testing the assembly you order, and the certification of a finished garment belongs to the garment maker who builds on it. Base-fabric test data cannot be transferred to a coated or laminated version — ask for the report for your construction, and read that report against the construction it names.

Who makes it

Who makes the laminate

Our textile manufacturing roots go back to 1972 and the company was established in Shantou, Guangdong in 2002. The substrates on this page — para-aramid woven cloth, aramid felt and UHMWPE cloth — are spun and converted in a 30,000 m² integrated plant, so the cloth under the coating is ours rather than bought in and coated.

This page covers the coated and laminated class as a whole: the aluminised and PU- or TPU-coated builds of the para-aramid range, the pre-oxidised felt laminate, and the coated UHMWPE constructions recorded for cut and puncture duty. Substrate, coating or foil, weight and width are set with the order, and each construction is quoted together with the substance position for the exact article, because in this class the two cannot be separated.

Textile manufacturing roots 1972
Integrated spinning and knitting plant 30,000 m²
Aramid, Modacrylic and HPPE yarn a year >1,000 tons
Protective fabric a year >500 tons

Technical data

Product information

The coated and laminated constructions our records carry, with the substrate, the coating or the foil, and the recorded weight and width. Every figure names its source. Where a record holds no figure — or holds two that disagree — we write On request instead of choosing one.

TPU and PU coated protective fabric
Model Substrate and coating Weight Width / thickness Rating or key property Source
WH501-05CA High-strength polyethylene, glass fibre, polyester, nylon and PU — single-sided black TPU coating 490 ± 20 g/m² 150 cm / 0.79 mm Cut and puncture resistant: luggage, cut and puncture reinforcement layer, pet tear-resistant builds TPU & aluminium catalogue
WH501-05CD High-strength polyethylene, glass fibre, polyester, nylon and PU — single-sided thickened black TPU coating 700 g/m² 150 cm / 0.88 mm Cut and puncture resistant, the thickened build of the same construction TPU & aluminium catalogue
WH501-26CA PE and polyester base fabric — single-sided black TPU coating 380 g/m² 145 cm / 0.68 mm A6 cut and puncture resistant TPU & aluminium catalogue
W002-1.5CD 100% para-aramid (aramid 1414) — double-sided flame-retardant grey PU coating 280 g/m² 160 cm Double-sided PU coated build on an inherently flame-resistant substrate TPU & aluminium catalogue
MCW-097 UHMWPE (HPPE) with TPU — single-layer PE coating 550 ± 60 g/m² 138 cm / 0.58 mm Not flame resistant — cut and puncture duty only TPU & aluminium catalogue
MCW-131.1 UHMWPE (HPPE) with TPU — three-layer base fabric with PE coating 2,000 g/m² 145 cm / 2.05 mm Not flame resistant — the heaviest coated construction recorded in the range TPU & aluminium catalogue

TPU and PU coated protective fabric

Aluminium foil laminated protective fabric
Model Substrate and foil Weight Width / thickness Rating or key property Source
WT-OP-370 Pre-oxidised fibre and para-aramid (aramid 1414) 370 g/m² 150 cm Flame-retardant pre-oxidised and para-aramid build TPU & aluminium catalogue
WT-OP-300AL Pre-oxidised fibre, para-aramid and aluminium foil 300 g/m² 150 cm High heat resistant, thermal-radiation resistant, flame retardant TPU & aluminium catalogue
WT-OP-470AL Pre-oxidised fibre, para-aramid and aluminium foil 470 g/m² 150 cm High heat resistant, thermal-radiation resistant, flame retardant TPU & aluminium catalogue
WP-AC-465AL Modacrylic and cotton blend base with aluminium foil 465 g/m² 150 cm / 0.75 mm High heat resistant, thermal-radiation resistant, flame retardant TPU & aluminium catalogue
MD-W002-3AL 100% para-aramid (aramid 1414) woven + aluminium foil 360 g/m² 150 cm Aluminised build, the construction this class records as improving radiant-heat performance; the code is pursued by testing the laminate Para-aramid catalogue
MD-W002-6AL Para-aramid (aramid 1414) woven + aluminium foil 415 g/m² 150 cm Aluminised build, for radiant-heat duty; established by testing the laminate Para-aramid catalogue
MD-S-405AL Para-aramid (aramid 1414) woven + aluminium foil 530 g/m² 120 cm Aluminised build at the heaviest recorded weight of the para-aramid range Para-aramid catalogue

Aluminium foil laminated protective fabric

Coated constructions on our other substrates
Construction Substrate and coating Weight Construction / width Rating or key property Source
Pre-oxidised felt laminate Pre-oxidised (oxidised PAN) felt + aluminium facing On request Nonwoven felt laminated with an aluminium facing; width on request No weight and no width is recorded for this laminate, so none is printed Product record
MD-W002-1.2CZ Para-aramid (aramid 1414) woven + PU coating 250 g/m² Woven plain + PU coating, 150 cm Coated build; the result belongs to the laminate and is established by testing it Para-aramid catalogue
MD-W002-8CD Para-aramid / polyester woven + PU coating 330 g/m² Woven plain + PU coating, 150 cm Coated build on a blended substrate; tested as the laminate Para-aramid catalogue
Coated UHMWPE (HPPE) twill, S-482 UHMWPE and polyester twill with a black coating 880 g/m² Woven twill, coated Not flame resistant — the base fibre melts rather than charring, so this is a cut and puncture construction only Legacy record

Coated constructions on our other substrates

The Source column names where each figure comes from: TPU & aluminium catalogue is our current TPU and aluminium product catalogue, Para-aramid catalogue is the internal catalogue of the para-aramid fabric range, Product record is the specification our records carry for that construction, and Legacy record is the construction as our legacy catalogue carries it. No rating, code or class is printed on these tables, because in this class the result belongs to the assembly: a coated or laminated construction is tested as a complete assembly and base-fabric test data cannot be transferred to it. One row above is a laminate our records carry without a weight or a width, so that cell reads On request rather than a figure no source states. The coated UHMWPE rows are cut and puncture constructions and are labelled as not flame resistant, because their base fibre melts. Where our records hold no figure we write On request rather than an estimate.

Made to order

Specification options

Substrate, coating or foil, weight and width are set with the order. Tell us the hazard the construction is written against and the screening list your programme works to, and we will confirm the construction and the material data that fit it.

Key specifications
Substrate Para-aramid (aramid 1414) woven cloth; pre-oxidised fibre; modacrylic and cotton blend; UHMWPE (HPPE) and high-strength polyethylene cloth
Coating or laminate PU or TPU coating (single-sided and double-sided); aluminium-foil lamination; the recorded constructions are listed in the tables above
Weight 250 – 2,000 g/m² recorded across the class: 380 – 2,000 g/m² for the TPU and PU coated builds, 300 – 530 g/m² for the aluminised builds, and 880 g/m² for the coated UHMWPE twill; the finished weight is set with the order
Width / thickness 120 – 160 cm recorded across the coated and aluminised builds, with thickness recorded from 0.58 mm to 2.05 mm; set against the cutting and spreading line the cloth runs on
Roll form Roll length on request — tell us the unwind length your line runs
Test route The laminate is tested as a complete assembly, arranged to the customer’s requirement and reported for the production lot
Substance position The substance declaration is issued for the exact article supplied — substrate, coating or membrane and adhesive accounted for separately

Colour in this class is decided by two things: the substrate underneath and the coating or foil on the face. Where the substrate is our para-aramid woven cloth, colour follows the fibre — para-aramid is practically impossible to piece-dye, so only solution-dyed shades such as natural yellow, black and navy are recorded for that range — and an aluminium-foil face is metallic by its nature. A coated build takes the colour of the coating system as well, and no shade card is held for the coated and laminated class, so the colour chips are not printed here. Send the shade reference your programme uses with the construction you are specifying, and we will confirm it with the coating line before the order is placed.

Standards and certification

A coated or laminated construction is supplied on material data for the construction, and this is the class we screen most carefully. The two items below are the ones we can stand behind today; the routes that have to be established by testing the assembly are named in the note, and none of them is printed above as a held result.

  • ISO 9001 Quality management system.
  • REACH SVHC Declaration available on request for the exact article supplied, coating or membrane, adhesive and substrate accounted for separately.

Nothing in this class is inferred from the composition. A coating or a laminate is a complete assembly, so every construction is tested as one, and base-fabric test data cannot be transferred to a coated or laminated version — ask for the report for your construction. The routes in this class, each arranged to the customer’s requirement and reported for the production lot, are: EN ISO 11612:2015, where the coated or laminated assembly is re-tested and a substrate report cannot substitute for it; EN ISO 11611:2015, which coated and laminated structures commonly serve under in welding protection; EN 343 / EN ISO 24232, the water penetration and breathability route this class is often bought for, where the class records Class 3 from 1,300 mm and Class 4 from 2,000 mm hydrostatic head and the class for a construction is established by testing it; EN 14325, the materials, seams and components standard that has to be passed before a chemical-protection Type classification is attempted; EN 13034, the Type 6 / 6B light-splash route, which is not protection against immersion or sustained chemical exposure; EN 14605 for Type 3 and Type 4; EN ISO 14116:2015 and EN ISO 15025:2016 at material level; EN 1149-1 and EN 1149-5, where a coating can interrupt the conductive path and a conductive base cloth has to be re-tested after coating; EN IEC 61482-1-1:2019, where the arc rating of a coated assembly is measured rather than taken from the substrate; and the ASTM material routes of ASTM F2700, ASTM D6413 and ASTM F1959. ASTM F1506-22 is a material-level specification with durability and after-wash requirements attached, so a coated or laminated construction may not reach it; test a sample of your construction before the order is committed. Under NFPA 2112 a coated fabric can be tested, but declaring the material to that standard requires third-party certification, and the certification of a garment belongs to the garment maker; NFPA 1970 is a finished firefighter- and rescue-equipment standard and coated laminated structures appear in it as outer and rescue layers. EN ISO 20471 and EN ISO 13688 are finished-garment standards and are not applied to this cloth; ANSI/ISEA 105 and ANSI/ISEA 138 are finished hand-protection standards, and the lettered cut and impact grades belong to the finished glove rather than to a roll of coated fabric. On the chemical side, REACH SVHC is mandatory for this class and is the highest screening risk on the site: the coating or the membrane is itself an article, phthalates used as plasticisers in PVC and flexible coatings are the live question, and a laminating adhesive can carry SVHC as well, which is why we ask for the coating supplier’s safety data sheet and substance declaration before a construction is quoted. REACH Annex XVII entry 43, the azo dye route, is arranged for a dyed or coated cloth on the same basis. RoHS is not a regulation that applies to textiles, so no RoHS position is stated for a coated article; where a programme screens for phthalates, the answer is the substance declaration for the exact article supplied. Test reports and certificate copies are available from our sales team on request.

Frequently asked questions

What does coated and laminated mean, and why can the substrate’s test data not be used?

A coated fabric is a cloth with a coating applied to one or both faces; a laminated fabric is a cloth bonded to a film, a membrane or a foil. Either way the construction has three components doing work — the substrate, the coating or foil, and the adhesive or bonding route — and the assembly takes its properties from all three. A flame-resistant substrate does not make a flame-resistant laminate: the coating can burn, drip or raise smoke density, and that changes the result of the whole construction. This is why base-fabric test data cannot be transferred to a coated or laminated version, and why every construction in this class is tested as a complete assembly.

Does an aluminium foil face improve the heat performance?

Yes, and it is the reason the aluminised builds are in the range. Aluminium-foil lamination substantially improves radiant-heat performance, which is the C code band of EN ISO 11612, and an aluminised construction is the version of this class that is worth putting forward for a high radiant-heat duty. It is a route to be proven rather than a result we can quote: the code your construction reaches is established by testing that construction, and we hold no report for a construction of this class, so no code is printed on this page.

Is a PU, TPU or PVC coating flammable?

A coating or a membrane is a component in its own right, and what matters is how the assembly behaves, not how the coating behaves alone: a coating that burns, drips or raises smoke density can make the overall burning behaviour of the laminate worse than that of the cloth it sits on, and a coating can also interrupt a conductive path in a base cloth that was built for antistatic duty. That is exactly why this class is tested rather than reasoned about. We do not state a combustion result for a coating on its own, and we do not state a result for a laminate until the assembly has been tested.

What does REACH require for a coated fabric?

More than for a plain cloth, and at article level. In a complex article the 0.1% SVHC threshold is assessed against each constituent article rather than against the whole, so the coating or membrane, the adhesive and the substrate each have to be accounted for. PVC and flexible coatings commonly use phthalate plasticisers, several of which are on the SVHC candidate list, and a laminating adhesive can carry SVHC too. In practice that means we ask the coating supplier for the safety data sheet and the substance declaration for the material in your construction, and the declaration we issue with the goods is issued for the exact article supplied. Azo dyes under REACH Annex XVII entry 43 are a tested route for a dyed or coated cloth. RoHS, for its part, is not a regulation that applies to textiles, so we state no RoHS position for a coated article.

Which weights and widths can you supply in this class?

The para-aramid coated and aluminised constructions are recorded from 250 g/m² to 530 g/m², at widths of 120 cm to 150 cm, and the coated UHMWPE constructions at 700 g/m² and 880 g/m². The pre-oxidised felt laminate carries no recorded weight or width in our records, so that laminate reads On request rather than a figure we would have to guess. Tell us the substrate, the duty and the roll form your line runs, and we will confirm the construction and its weight and width for the order.

Do you supply a coated UHMWPE fabric, and is it flame resistant?

Yes, two coated UHMWPE (HPPE) twills are recorded in this class, at 880 g/m² and 700 g/m², and both are cut and puncture constructions. Neither is flame resistant: the base fibre melts rather than charring, which is why no flame, heat, arc or molten-metal requirement is offered for them, and why the lettered cut grades a glove or a sleeve carries are issued on the finished article rather than on a roll of coated cloth. If the hazard is heat or flame rather than a sharp edge, an aluminised or coated aramid build is the right material in this class.

How is the performance of a laminate verified before ordering?

Ask for the test report for the production lot, and read it against the construction it names, because in this class the result belongs to the assembly and not to the substrate. Weight, width, substrate and coating are recorded per lot. Where your approval file needs a standard-referenced result on the construction, the testing is arranged to your requirement and reported for the lot, and where your own route needs an independent laboratory result, third-party test reports can be provided on request. The certification of a finished garment built on the laminate belongs to the garment maker.

Let’s talk about your fabric requirements

Tell us the application, the required weight and the standard you need to meet. Our technical team will come back with a matching fabric, the spec sheet and a quotation.